Panel Guide
Pyronix Euro 76 & 162 – RS232
Panel Connection – Serial RS232
Manufacturer | Pyronix |
Model | Euro |
Version | 76 & 162 |
Minimum DualCom Pro Firmware | DualCom Pro: V2.24 |
Minimum Panel Firmware | V9.10ar or greater for V10, use Pyronix Euro guide |
Cable required? | Lead Provided with DualCom Pro |
Panel Profile | Pyronix-Euro-RS232 |
Panel Bus Connection | RS232 |
Technical Notes | See below. |
Panel Connection Information
Manufacturer | Panel | Connection | Cable/Plug On | Supplied Cables |
Pyronix | Euro | RS232 | 6 Pin | Green – RTN |
Panel Programming
- Go to “Engineer Mode” > Programme ‘ARC/SMS’ or ‘SMS’ call
- ‘ARC/SMS is’ will be displayed. Select ‘Enabled’ [0] > Select ‘ARC Details’ > Select ‘Format’ [141], ‘WebWayOne’ will be displayed
- Select ‘SIA Ack Char’ [006] >Select ‘SIA Nack Char’ [021] > ‘Valid Areas’ Engineer’s choice
- ‘Area Accounts’ Engineer’s choice > Select ‘ARC Account’ (Site ID/Account No.)
- Select ‘Content’ [17-32] Engineer’s choice (25 and 28 enable restores, see full table in troubleshooting below)
- Select ‘Redials’ [03] > Select ‘Time out’ [30] > Exit “Engineer Mode” into “Day Mode”
Hints and Tips
- To stop the panel reporting line fault to the keypad
- Engineer Mode > System Timings > Set Line fault to 250
Remote Access Programming
- Enter engineer mode and press NO until “SET UP DOWNLOADING?” is displayed, then press YES.
- Go to ‘Set Up Downloading’
- Set “Download by” to (WebWayOne) [4]
- Set “Poll Timeout” [10]
- Set “Modem Init Timeout” [060]
- Set “Rings to Answer” [1]
- Set “Comm Tx Timeout” [030]
- Set “Comm Dial Tmout” [030]
- Set “UDL Tx Timeout” [02]
- Set “Redials” [03]
- Set “Roving Dial” to No [0]
- Set “Auto Upload” to “No” [0]
- “UDL Password” is Engineer’s choice
- “Site Name” is Engineer’s choice
- Go into “Communications Menu” and select “No “until “Advanced Communications”
- Press “Yes” until “ARM PC Tel NO.” and enter 1111