Panel Guide

Pyronix Euro 46 V9 – RS232

Panel Connection – Serial RS232

Manufacturer

Pyronix

Model

Euro

Version

46

Minimum DualCom Pro Firmware

DualCom Pro: V2.24
DualCom Pro 2: V2.0.1

Minimum Panel Firmware

V9.10ar or greater for V10, use Pyronix Euro guide

Cable required?

Lead Provided with DualCom Pro

Panel Profile

Pyronix-Euro-RS232

Panel Bus Connection

RS232

Technical Notes

See below.

Panel Connection Information

Manufacturer

Panel

Connection

Cable/Plug On

Supplied Cables

Pyronix

Euro/Enforcer

RS232

6 Pin

Green – RTN
Blue – RS232-R
Red – RS232-T

Wiring Diagram

Panel Programming

  • Go to “Engineer Mode” > Programme ‘ARC/SMS’ or ‘SMS’ call
  • ‘ARC/SMS is’ will be displayed. Select ‘Enabled’ [0] > Select ‘ARC Details’ > Select ‘Format’ [141],
    ‘WebWayOne’ will be displayed
  • Select ‘SIA Ack Char’ [006] >Select ‘SIA Nack Char’ [021] > ‘Valid Areas’ Engineer’s choice
  • ‘Area Accounts’ Engineer’s choice > Select ‘ARC Account’ (Site ID/Account No.)
  • Select ‘Content’ [17-32] Engineer’s choice (25 and 28 enable restores, see full table in
    troubleshooting below)
  • Select ‘Redials’ [03] > Select ‘Time out’ [30] > Exit “Engineer Mode” into “Day Mode”

Hints and Tips

  • To stop the panel reporting line fault to the keypad
  • Engineer Mode > System Timings > Set Line fault to 250

Remote Access Programming

  • Enter engineer mode and press NO until “SET UP DOWNLOADING?” is displayed, then press YES.
  • Go to ‘Set Up Downloading’
  • Set “Download by” to (WebWayOne) [4]
  • Set “Poll Timeout” [10]
  • Set “Modem Init Timeout” [060]
  • Set “Rings to Answer” [1]
  • Set “Comm Tx Timeout” [030]
  • Set “Comm Dial Tmout” [030]
  • Set “UDL Tx Timeout” [02]
  • Set “Redials” [03]
  • Set “Roving Dial” to No [0]
  • Set “Auto Upload” to “No” [0]
  • “UDL Password” is Engineer’s choice
  • “Site Name” is Engineer’s choice
  • Go into “Communications Menu” and select “No “until “Advanced Communications”
  • Press “Yes” until “ARM PC Tel NO.” and enter 1111