Panel Guide
Pyronix Euro, Enforcer and CPX – Dial Capture
Panel Connection – Dial Capture
|
Manufacturer |
Pyronix |
|
Model |
Euro/Enforcer/PCX |
|
Version |
Pro 1 Min V2.33 Pro 2 Min V2.07 |
|
Minimum DualCom Pro Firmware |
DualCom Pro: V2.33 |
|
Minimum Panel Firmware |
V5.1 |
|
Cable required? |
N/A |
|
Panel Profile |
PYRONIX-EURO-ENFORCER-MCM |
|
Panel Bus Connection |
MCM Min V 2.05 |
|
Technical Notes |
For UDL the CSL Remote Manger needs to be V1.6.3.0 or greater. |
Panel Connection Information
|
Panel |
DualCom Pro |
|
PSTN A |
DualCom Pro 1 – MCM plug-on module – Line A |
|
PSTN B |
DualCom Pro 1 – MCM plug-on module – Line B |
Panel Programming
- Go to Engineering Mode
- Go to programme Digi/SMS call
- Select Disable Digi/SMS <0>
- Select ARC Details <1>
- Select Active
- Select format SIA (Option 129)
- Select first number <01666111>
- Select second number <01666222>
- Select valid areas (select areas to be reported)
- Select stop on success (yes)
- Select ARC account
- Select content 1-16 (recommend 1-5, & 7-13)
- Select content 17-32 (recommend 21-25, 27-30, & 32)
- Select redials <03
- Select time out <15>
- Select test calls (No)
Remote Access Programming
- Enter engineer mode and press NO till “SET UP DOWNLOADING?” is displayed, press YES.
- Download by (None (0)) is displayed, press 1, Download by Modem (1) is now displayed, press YES.
- Security Mode (Auto Answer (0)) is displayed, this is correct. Press YES.
- Telecom Line (Dedicated (0)) is displayed, this is correct. Press YES.
- Number of Rings to Prime (01) is displayed, this part is irrelevant so can be left at factory default. Press YES.
- Modem Speed (High (1) is now displayed, this is correct. Press YES.
- ARM PC telephone number 123456
- Continue pressing YES until Programme PC’s is displayed, press yes, PC1 is now displayed, enter
- Panel programming is now complete, come out of engineer menu to save changes