Panel Guide

Texecom Premier – TTL

Panel Connection – TTL

Manufacturer

Texecom

Model

Premier

Version

60, 88, 168, 816

Minimum Panel Firmware

V1.x V10.x

Cable required?

Provided with DualCom Pro

Panel Profile

TEXECOM PREMIER TTL

Panel Bus Connection

TTL

Technical Notes

Premier Range has been phased out.

Note SIA string special character issue in troubleshooting section.

Panel Connection Information

Manufacturer

Panel

Connection

Cable/Plug On

Supplied Cables

Texecom

Premier/Elite

TTL

5 Pin (cable removed)

Green – RTN
Blue – TTL-R
Red – TTL-T

DualCom Pro to Panel Wiring

Wiring Diagram

Panel Programming

  • Enter “Engineer Mode”
  • In Options Menu” – “Enable Communicator” must be ticked > UDL passcode (set in the panel) must match> Dial attempts 1, ring before answer 3
  • In “ARC Menu” – “Account number” (site ID) > “SIA Level 2/3” > “Connect Via IP” – ticked > “Send SIA text” – ticked
  • In “Radio-Pad and Com Port Options Menu” – Under “Set Com Port 1” to – “WebWayOne module” > Local IP address – 127.0.0.1 >Local IP Port – 50561 > Gateway – 127.0.0.1 > Subnet Mask – 255.255.255.0 > Name/SMG Port – 50561
  • Log out of “Engineer Mode” to establish electrical connection

Troubleshooting

  • The DualCom Pro should be connected to Com Port 1
  • If only Com Port 2 or 3 is available: Make sure the baud rate (modem speed) is set to 19200
  • If the Texecom is being programmed with a laptop on Com Port 2, the DualCom Pro is
    connected to Com Port 1 the device will be lost from the panel until the Wintex session is closed
  • Only the alarm format SIA is supported

Technical Notes

Line fault is through the serial interface, no extra settings are required in either the panel or the DigiAir/DualCom Pro. 

If certain PA restores are not coming through, please ensure that within Area Programming, option 21 (Unarmed Tamper/ Fault Comms) is turned ON.