Panel Guide

Orisec – CP Range – TTL

Panel Connection – TTL

Manufacturer

Orisec

Model

CP Range

Version

CP-20 CP-25 CP-30 W-CP-40 CP-50
CP-100 CP-200

Minimum Panel Firmware

CP-20 V1.00 CP-25 V1.10 CP-30 V3.10 W-CP-40 V1.42 CP-50 V1.84 CP-100 V1.84 CP-200 V1.84

Cable required?

Provided with the DualCom Pro

Panel Profile

Orisec-CP-TTL

Panel Connection

TTL

Panel Connection Information

Manufacturer

Panel

Connection

Cable/Plug On

Supplied Cables

Orisec

All

TTL

4 Pin (cable provided)

Green – RTN
Blue – TTL-T
Red – TTL-R

Wiring Diagram

 

Panel Programming

  • Enter “Engineering Mode” using the “Engineer Code”, followed by the “Manager
    Code”
  • “Programming Menu” > Navigate to “ARC-Setup Menu” 17

Insert or Modify the following:

  • Account = ARC Account ID
  • Protocol = SIA3 or Contact ID
  • Dial Seq = 2
  • Reported = Set triggers as required
  • Area = Set areas as required
  • IP Address = Clear value
  • IP Port = Clear value
  • Exit back to “Programming Menu”
  • Select “Com Port Setup Menu” 13

Insert or Modify the following:

  • Com Port = 1
  • Mode = DualCom Pro
  • Exit “Engineering Mode”

Technical Notes

Line fault is through the serial interface, no extra settings are required in either the panel or the DigiAir/DualCom Pro.

When configuring the panel, only the COM Port in use should configured as DualCom Pro. If both ports are configured, then the panel will operate incorrectly.

Please ensure that the ARC Account field within individual Areas is left blank. Any number entered in this field will override the global account number of the panel for activations within this area.