Panel Guide

Menvier TS – TTL

Panel Connection – TTL

Manufacturer

Menvier

Model

TS Series

Version

TS 690, TS 790, TS 900, TS 2200, TS 2500

Minimum Panel Firmware

MIN V5:1

Cable required?

Unterminated serial cable with 8 Way Molex type socket

Panel Profile

MENVIER-TS-TTL

Panel Bus Connection

TTL

Technical Notes

When on menu 1 press ENTER to get to menu 2. Press A to remove any additional digits if accidentally entered.

Panel Connection Information

TTL T

Molex Pin Out 7

TTL R

Molex Pin Out 8

RTN

Molex Pin Out 2

Panel Programming – TS 690

  • Engineer menu 2
  • C – Modem options
  • 1. Callback No 1 – 123456
  • Callback No 2 – No setting
  • .Callback No 3 – No setting
  • Password – This must match the password configured in the Downloader application account setup
  • Modem site No –This must match the site ID configured in the Downloader application account setup
  • Digi Programming
  • Telephone No 1 No setting
  • Telephone No 2 No setting
  • Account No 1 No setting
  • Account No 2 No setting
  • Reports 1 No setting
  • Reports 2 No setting
  • Set/Day No setting
  • Restore No setting
  • Digi Idle No setting
  • Select Mode (Direct Access)
  • Select test calls (No)
  • Exit Engineer Mode into Day Mode

Panel Programming – 790/900/2200/2500

  • Engineer menu 2-
  • C – Modem options
  • 1. Callback No 1 123456
  • Callback No 2 No setting
  • Callback No 3 No setting
  • Modem site No- This must match the site ID configured in the Downloader application account setup
  • T Modem site No- This must match the site ID configured in the Downloader application account setup
  • Digi Programming-
  • Telephone No 2 No setting required
  • Telephone No 3 No setting required
  • Account No 1
  • Account No 2 No setting required
  • Account No 3 No setting required
  • Reports to No 1 Set all reports on
  • Reports to No 3 Set all reports on
  • Set/Day Set all reports on
  • Restore Set all reports on
  • Invert Set all reports on
  • Dialling mode Consecutive
  • Test call period Disabled
  • Digi output 1 is Line fault
  • Digi output 2 is Line fault
  • Extended format Full report
  • TOS calls are Disabled
  • Ring count is Instant