Honeywell Galaxy Classic – Dial Capture

Panel Connection – Dial Capture

Manufacturer

Honeywell

Model

Galaxy Classic Range

Minimum Panel Firmware

4.5 and above

Cable required?

MCM connected to:

  • DualCom Pro 1 – MCM plug-on module CS.1.402
  • DualCom Pro 2 – DI & AL

Panel Profile

Honeywell-Galaxy-MCM

Panel Connection

Dial Capture

DualCom Pro to Panel Wiring

DualCom Pro 1 – MCM plug-on module – Line A
DualCom Pro 2 – DI

PSTN A

DualCom Pro 1 – MCM plug-on module – Line B
DualCom Pro 2 – AL

PSTN B

Panel Configuration

  • Enter Engineering Mode – Menu 56
  • Select Internal Telecoms (Option 1)
  • Select Format (Option 1)
  • Enter SIA (Option 2)
  • Select SIA level 3
  • Turn on reporting triggers as needed (recommend 10 and 18)
  • Select Tel No.1 (option 2)
  • Set a dummy phone number, for example 01234 567890
  • Select Account Number (option 3)
  • Enter ARC Connection ID – see My Base
  • Go to Remote Access (Option 12)
  • Select Access Period – 4 Anytime
  • Select Mode 1 – Direct Access
  • Escape to return to Engineering Mode
  • Exit Engineer Mode into Day Mode