Panel Guide

Honeywell Galaxy 8, 16, 16+ – Dial Capture

Panel Connection – Dial Capture

Manufacturer

Honeywell

Model

Galaxy 8, 16, and 16+

Minimum Panel Firmware

1.4

Cable required?

MCM connected to:

  • DualCom Pro 1 – MCM plug-on module CS.1.402
  • DualCom Pro 2 – DI & AL

Panel Profile

Honeywell-Galaxy-MCM

Panel Connection

Dial Capture

DualCom Pro to Panel Wiring

DualCom Pro 1 – MCM plug-on module – Line A
DualCom Pro 2 – DI

PSTN A

DualCom Pro 1 – MCM plug-on module – Line B
DualCom Pro 2 – AL

PSTN B

Panel Configuration

  • Enter Engineer Mode
  • Go to Menu 12 Comms 1
  • Menu 01 set Account/Site ID
  • Menu 02 set Tel No.1 to a telephone number (Ex 01666111)
  • Menu 03 clear Tel No.2
  • Menu 04 set Format to SIA0
  • Menu 06 set Dial Type to DTMF Dial
  • Menu 07 set required Triggers
  • Menu 10 set Access to Direct
  • Go back to top menu structure
  • Go to Menu 13 – Comms 2
  • Menu 01 set No. of Rings to 1
  • Exit Engineer Mode