Panel Guide

Menvier M-Series – RS232

Panel Connection – RS232

Manufacturer

Eaton

Model

Scantronic/Menvier M-Series

Version

M1000 and M2000

Minimum Panel Firmware

MIN V1:01

Cable required?

Menvier-M-RS232

Panel Profile

MENVIER-M-RS232

Panel Bus Connection

Unterminated serial cable with 9 Way D-Type IDC socket

Panel Connection Information

Connection

Panel

RS232-T

9 Way D-Type Pin 2

RS232-R

9 Way D-Type Pin 3

RTN

9 Way D-Type Pin 5

Panel Programming

  • Go to Engineer Level 2
  • Option 5 Communications
  • Option 2 Digicom
  • Option 1 Comms Format
  • Set to Option 7 – Extended SIA level 3
  • Option 2 ARC No 1
  • Set telephone number to <01666111>
  • Back to Digicoms option 2
  • Option 3 for account numbers
  • Enter the Account Number 1 <_______>
  • Option 4 Dialling mode Should be set to – Consecutive –
  • Option 5, Options
  • Option 1 Restore signals select
  • Option 2 Fast Format <8FF Channels>
  • Back to Digicoms Option 2
  • Option 6 CID/SIA reports set to [Full]
  • Back to Engineer Level 2
  • Option 5 Communications
  • In Option 4 RS232 options
  • Ensure Option 1 – Select RS232 baud <38400>
  • And Option 2 – Select Remote Modem
  • Back to Go to Engineer Level 2
  • Option 5 Communications
  • Select Option 1 downloader
  • Enter Option 1 and Select Password <______> (same as configured in downloader application)
  • Communications Option 5
  • Select Option 1 – Downloader
  • Set Option 3, Select access mode to – Unattended –
  • Set Option 4, Edit call No 1 to – BLANK
  • Option 5 Modem Options ensure
  • Option 1 – Select rings to answer Option 1 is – Immediate
  • Option 2 – Select baud rate – 1200 – (2400 if available)