Panel Guide

Aritech Advisor Master – RS232

Panel Connection – RS232

Manufacturer

Carrier

Model

ATS Advisor Master plus serial plug on module

Minimum Panel Firmware

Please refer to panel manufacturer

Cable required?

See photo below.

Panel Profile

ARITECH-MASTER-RS232

Panel Bus Connection

RS232

Panel Connection Information

Connection

Panel

RS232-T

RXD

RS232-R

TXD

RTN

GND

CTS

A+

Cable Required

Wiring

Panel Programming

Menu 9 – Communications menu

  • PBX [not set]
  • MSN [not set]
  • DT Detection [UK]
  • DTMF tone dialling [Yes]
  • Enable PSTN line fault monitor [No]
  • Monitor service tones [No]
  • 3 digit SIA extensions [Yes]
  • ISDN point to point [No]
  • Enable ISDN line fault monitor [No]
  • 3 digit SIA extensions [Yes]
  • 200 baud reverse area open/close [No]
  • X25 TEI value [2]
  • Audio listen in time [180]
  • Audio listen in frame time [30]
  • Report mains fault [Yes]
  • Report line fault [Yes]
  • Enable GSM line fault monitor [No]
  • Central station
  • CS No <1> Enter
  • Format No: (Option 7)
  • Ph1
  • Ph2 [not set]
  • Acc No: system account number
  • Acc No: area 1 account number
  • Bell modem: [Yes]
  • Dual reporting [No]
  • Listen in [No]
  • Disable reporting inhibits [No]
  • Reserved [No]
  • XSIA Max characters [30]
  • X25 account code not important
  • Conn type (Option 4)
  • suppress FTC for voice reporting [No]
  • Retry count [10]
  • SIA Area Modifier [Yes]
  • X25 D-bit [No]
  • Mains Fail Reporting delay [30]
  • Enable IP Line Fault Monitor [No]
  • AWDGP reporting codes for IMQ [No]

Menu 29 – Computer Connections menu

  • Enable Remote UpDownload [Yes]
  • Up/Download if any area armed [Yes]
  • Enable Remote Control [Yes or No]
  • Remote Control if any area armed
  • Use modem Init [No]
  • Report Alarms to computer [No]
  • Report Access to computer [No]
  • Cmp, Cbk, Srv
  • Computer Address [0001]
  • Security Password [0000000000]
  • Security Attempts [255]
  • Number of Rings [1]
  • Number of Calls [0]
  • Answer Machine [No]
  • Reserved [No]
  • Bell Modem [No]
  • Conn Type * (Option 4)
  • PC connections authorised [No]

Troubleshooting

  • Note for ATS 2000 panels set the connection type here as PSTN. Rather than serial interface. The connection type in menu 9 needs to remain as Universal Interface.
  • *Please note without 12V to the CTS connection on the serial interface the serial board will not operate.