Visonic PowerMaster – Dial Capture
Panel Connection – Dial Capture
Manufacturer | Visonic |
Model | PowerMaster |
Version | Below |
Minimum DualCom Pro Firmware | DualCom Pro: V2.34 |
Minimum Panel Firmware | MCM version less or equal to V1.05 – Needs SPT version less or equal to V2.06 |
Cable required? | Provided with DualCom Pro |
Panel Profile | VISONIC-PMAX/MASTER-MCM |
Panel Bus Connection | MCM |
Technical Notes | Reporting of DualCom Pro path states to the panel is not supported via the serial interface. [Please use the DualCom Pro Outputs] ** UPDATE ** UK Panel Firmware V3.3.3 (UK only) – All tested and working fine on SIA & UDL via the DualCom Pro. |
Panel Connection Information – if using an RJ11 Connector
SPT | Panel |
MCM plug-on module – Line a | RJ11 Pin 3 |
MCM plug-on module – Line b | RJ11 Pin 4 |
Panel Connection Information – if NOT using an RJ11 Connector
SPT | Panel |
MCM plug-on module – La (DI for PRO 2) | Left terminal of the 2 “line” terminals |
MCM plug-on module – Lb (AL for PRO 2) | Right terminal of the 2 “line” terminals |
Panel Programming
- Enable “Installer Access” – Default user code = 1111 > Press the “Unlock Icon” button > Enter
“User Code” - Enter “Engineer Mode” > Press “OK” > Enter “Installer Code”
- Enter “Communications Menu” > Press “OK”
- Navigate to “C.S. Reporting” > Press “OK” > At “1st RPRT CHAN” > Press “OK” > Select “PSTN”
> Press “OK” - Under “2nd RPRT CHAN” > Press “OK” > Select “Disabled” > Press “OK”
- Navigate to “RCVR1 Account” > Press “OK” > Enter “Account Number” (chip number) > Press
“OK” - Go to “PSTN/GSM RCV1” > Press “OK” > Insert a “Telephone Number” (example:
01234567890) > Press “OK” - Navigate to “PSTN Format” > Press “OK” > Select “SIA” > Press “OK” > Press “ESC”
- Navigate to “Up/Download” > Press “OK” > Navigate to “PSTN Up/Download” > Press “OK”
- Enable “Remote Access”
- Press “ESC” button to make the changes take effect