Panel Guide

RISCO Gardtec – Dial Capture

Panel Connection – Dial Capture

Manufacturer

RISCO

Model

Gardtec 600 Series

Version

N/A

Minimum Panel Firmware

N/A

Cable required?

MCM connected to:

DualCom Pro 1 – MCM plug-on module CS.1.402
DualCom Pro 2 – DI & AL

Panel Profile

GARDTEC-MCM

Panel Connection

Dial Capture

Technical Notes

Only SIA is supported.

If Fast Format is required use GENERIC-ALARMS-MCM as Panel Profile.

DualCom Pro to Panel Wiring

DualCom Pro 1 – MCM plug-on module – Line A
DualCom Pro 2 – DI

PSTN A

DualCom Pro 1 – MCM plug-on module – Line B
DualCom Pro 2 – AL

PSTN B

PCB

Panel Configuration

Set up Alarm Format:

  1. Enter Keypad Access Code to get into Engineer mode (Default is 1234) followed by [YES]
  2. Press [3] [4] [YES] to jump to Digicom
  3. Press [NO] until you see ‘Mod + SIA’
  4. Press [YES]
  5. Press [0]
  6. Press [NO] until you see ‘Program Digicom Type or Test?’
  7. Press [NO] until you see ‘Program Digicom Functions?’
  8. Press [YES] [YES] (To change channels/triggers)
  9. Press [NO] once
  10. Press [YES] until the “>” appears next to PA
  11. Press [NO] to change the ‘Off’ to ‘On’
  12. Press [YES] [YES]
  13. Press [0] repeatedly to get out of Engineer mode

Set up Communication and line monitor security:

  1. Enter Keypad Access Code to get into Engineer mode (Default is 1234) followed by [YES]
  2. Press [3] [4] [YES] to jump to Digicom
  3. Press [0] (go back)
  4. Press [NO] until you see ‘Functions’
  5. Press [YES]
  6. Press [NO] until you see ‘Comms Functions’
  7. Press [YES]
  8. Press [NO] until you see‘Comms=On’
  9. Press [YES]
  10. Press [NO] and key in the required Site Code/Id
  11. Press [YES]
  12. Press [NO] and key in the required ARC telephone number
  13. Press [YES]
  14. Press [YES] till you see ‘Line Monitor’
  15. Press [NO] till you see ‘Line Volts’
  16. Press [YES]
  17. Press [[NO] till you see ‘Line Security’
  18. Press [NO]until ‘Low’ to set Line Monitor to low security
  19. Press [YES]
  20. Press [0] multiple times to get out of engineer mode