Panel Guide
Honeywell Galaxy 8, 16, 16+ – Dial Capture
Panel Connection – Dial Capture
|
Manufacturer |
Honeywell |
|
Model |
Galaxy 8, 16, and 16+ |
|
Minimum Panel Firmware |
1.4 |
|
Cable required? |
MCM connected to:
|
|
Panel Profile |
Honeywell-Galaxy-MCM |
|
Panel Connection |
Dial Capture |
DualCom Pro to Panel Wiring
|
DualCom Pro 1 – MCM plug-on module – Line A |
PSTN A |
|
DualCom Pro 1 – MCM plug-on module – Line B |
PSTN B |
Panel Configuration
- Enter Engineer Mode
- Go to Menu 12 Comms 1
- Menu 01 set Account/Site ID
- Menu 02 set Tel No.1 to a telephone number (Ex 01666111)
- Menu 03 clear Tel No.2
- Menu 04 set Format to SIA0
- Menu 06 set Dial Type to DTMF Dial
- Menu 07 set required Triggers
- Menu 10 set Access to Direct
- Go back to top menu structure
- Go to Menu 13 – Comms 2
- Menu 01 set No. of Rings to 1
- Exit Engineer Mode