Texecom – Premier & Elite UDL Guide

DualCom Setup

  • Place the Texecom panel in engineer mode
  • Connect the aerial provided to the DualCom
  • Connect the DualCom directly to the COM 2400 board via the “to panel digi” port on the DualCom
  • The DualCom will go through its power-up/registration process, which will take approximately 2-3 minutes
  • The top “SVC” LED will start to pulse like a heartbeat once locked onto the network
  • The signal strength will then be displayed
  • Leave the DualCom to conduct an internal network survey – this will happen automatically. The display will show 0.0, 0.1, 0.2, etc
  • Once the survey is complete, you then need to proceed to panel programming
  • If triggered inputs on the DualCom are being utilised in fast format, then proceed to “Panel Programming (UDL)”
  • Panel Programming (SIA)
  • Enter the engineering menu
  • Press the down arrow until you reach “UDL/Digi Options”, then press YES
  • Press the down arrow until you reach “Program Digi”, then press YES
  • The display shows “ARC 1 Protocol Disabled”. Press NO and then the down arrow until “SIA Level II” is displayed
  • Press YES, then YES again, and the display shows “Primary No”. Press NO and enter number 01, followed by YES
  • Press down arrow once to “Secondary No”, then press NO and enter number 01 followed by YES
  • Press YES until “Account Number” is displayed, press NO, then enter the DualCom’s chip number followed by YES
  • Press down arrow to “Config (* * * * * * * *)”, press NO then down arrow until Send SIA Text is displayed, press NO, and the display will now show “Send SIA Text (* * * * * * * T)”, press YES
  • Press menu then down arrow until “Digi Options” is displayed, press YES
  • “Digi Options (* * * * * *)” is displayed, press NO twice
  • Display will now show “Digi is Enabled (E * * * * *)”, press YES
  • Unit is now set up to send SIA to the ARC via the dial capture ports

Panel Programming (UDL)

(Note if you have completed SIA programming then skip to point 5)

  • From engineering menu press down arrow until you reach “UDL/Digi Options”, press YES
  • Press down arrow until “Digi Options” is displayed, press YES
  • “Digi Options (* * * * * *)” is displayed, press NO twice
  • Display will now show “Digi is Enabled (E * * * * *) press YES then menu
  • Press down arrow until you reach “UDL Options” press YES
  • Press down arrow until you reach “UDL Password” factory default is 1234, this is optional if you wish to change then press NO and enter your password followed by YES
  • Press down arrow until “UDL Options (* *MD * * *) is displayed ? The “D” needs removing, press NO then number 3, display now should show (**M****), press YES
  • Press down arrow until “Rings Required” is displayed, factory default is “005” press NO and change to 001, press YES
  • Press menu followed by down arrow to “Setup Modules” press YES
  • Press down arrow until “Modem Speed” is displayed. Ensure this is set to 2400, if not press NO until 2400 is displayed then press YES
  • Press menu followed by the down arrow until “Com Port Setup” is displayed, press YES
  • “Onboard Digicom (Com300 Module)” is now displayed, press NO then down arrow until “Com2400 Module” is displayed, press YES
  • Unit is now setup for UDL

Things to consider on installation

  • Make a note of the panel’s Make, Model and Version e.g. Elite, 48, version x2
  • This information is critical when setting up a file in Wintex from where ever your UDL connection is being made from.