CSL Connected with Orisec

GUIDE

ARC CONNECTION

CSL Connected allows you to connect the following control panels to your chosen ARC via Orisec Cloud Services: CP/CK/CT-20, CP/CP/CK-60, W-CP-40-K/T/E, CP-50/100/200. Communication can be made in SIA II, SIA III*, Contact ID or Fast Format, using the applicable communication device (Single path
modules – CM2-GSM, CM2-IP, CM2-Wi-Fi. Dual path modules – CM2-GSM-GSM, CM2-GSM-IP, CM2-WiFi-GSM).

*SIA III is the preferred signalling method.

PANEL PROGRAMMING

Within the Orisec engineering menus, navigate to the following sections to program the required information:

Programming Menu > Comms Modules:

GSM settings (for all variants which include GSM)

  • APN Name – geminit2.m2m
  • User / APN2geminit2.m2m (only required if using dual radio – otherwise leave blank)
  • APN Password – leave blank

Note – if DHCP is being utilised, no information is required in these menus.

Ethernet settings (for all variants which include LAN)

  • Address – add site IP details if required
  • Port – add site IP details if required
  • Mask – add site IP details if required
  • Gateway – add site IP details if required

Note – if DHCP is being utilised, only the router’s SSID and password are required in these menus.

Wi-Fi settings (for all variants which include Wi-Fi)

  • SSID – Enter the router’s SSID
  • Password – enter Wi-Fi password
  • Address – add site IP details if required
  • Port – add site IP details if required
  • Mask – add site IP details if required
  • Gateway – add site IP details if required

SINGLE PATH SYSTEMS

Programmming Menu > ARC setup:

ARC: 1
Number – Enter ARC code from page 2
Account – enter chip/account number from ARC
Protocol – enter chosen protocol – default SIA III
Dial Seq – enter 555

DUAL PATH SYSTEMS

Programmming Menu > ARC setup:

ARC: 1
Number – Enter ARC code from page 2 followed by DP grade (ie 12345DP2)
Account – enter chip/account number from ARC
Protocol – enter chosen protocol – default SIA III
Dial Seq – enter 555

Programming Menu > System Options > Monitor H/W:

Enable both these options
– Report Single Path Fault
– ATS Path Faults

ARCCODEARCCODEARCCODE
1st County Monitoring26747DS Operations37687RE:SURE Intelligence73440
4i Security44650East Midlands Central Station32749Regio73046
Abel Alarm Company22567Farsight Security Services32058Remote Watch Monitoring66431
Advanced Signal Monitoring27649Fenix Monitoring33647Scamp Security72232
AIM Manchester24654G4S Belfast44786Scutum Digital Harlow93617
Alarm Control 2425242G4S Dublin44562Scutum Digital Plymouth73734
Alarm Meldnet BV63556GB Monitoring42699Securi-plex31731
ARC Monitoring27264IVP46768Securitas73283
Aspire Monitoring Services26125Marlowe62529Sefton Security Services73330
BHP24030MCM Cork62630Senate Group73192
Bouygues26018Mercury Security Management63732Sharp Group Fire and Security74218
Britannia Monitoring Service34782MiTec64763SitexOrbis74744
BSecure Monitoring Solutions27357MPL Alarm & Communicatie Centrale BV67594Smart Monitoring76720
Cerberus Security & Monitoring23514MVTEK68020SMC (Custodian)76270
Chubb Ireland25750National Monitoring Network62766SMC Nederlands (SMCNL)76324
Chubb UK24708National Monitoring (UK)62098Southern / Northern Monitoring76527
Churches24183Nederlandse Veiligheidsdienst Groep68445SSS Management Services77774
Connelly Glasgow26630Netwatch Ireland63668The Shield Group74430
Corps Monitoring Centre26492NightGuard64455Tyco Netherland86537
Cougar Monitoring26500P&R Fire & Security72789Uniqwin86400
Crime Prevention Services27732Pointer – Glasgow76473ViewControl84356
Crimewatch Monitoring Services27463PraxIS Group N.V77222VPS22450
Devision Netherlands33482Professional Witnesses Limited (PWG)77628
Diamond Point Ltd34294QVIS Monitoring78447

ACCESS THE APP

CSL Connected is fully compatible with all Orisec applications, Control Plus, Control Plus 2, Orisec UDL & Orisec Cloud Services.

For additional information on Orisec control panels, software packages or technical support please contact Orisec:

Email: support@orisec.co.uk
Phone: 01706 398740

TROUBLESHOOTING

Q. My ARC does not appear in the list provided?
A. It may be that your chosen ARC is not one of the many ARCs that have signed up for this solution. Please contact CSL Technical Support.

Q. What grade is the product?
A. Single path units are sold as EN50136-1:2018 SP2. Dual path units are sold as EN50136-1:2018 DP2

Q. How do I know that my signals are being sent to CSL’s Gemini Platform?
A. Once you have your system on test with the ARC, enter the programming menu, select test and diagnostics and then do test calls. Whilst in this menu push enter on any test signal and ensure that 2 ticks are shown on the panel. This indicates that the test alarm has been sent to Gemini. You should always check with the ARC that they have received signals at their end too.

Q. Am I able to send signals in a different format to the one which was ordered?
A. Yes this is possible and can be selected in the panel. Please check with your ARC before making any changes to make sure that they will accept the new format.

Q. What set up do I need to do on the Orisec Cloud Services?
A. There is no set up required on Orisec Cloud Services.

Q. Why can I not see the second APN option in the panel menus?
A. For dual path devices the following software versions are required

CONTROL PANELSOFTWARE VERSION
CP-20/ CP-60Version 5.42 onwards
CK-20/ CK-60Version 5.42 onwards
CP-50/ CP-100/ CP-200Version 8.22 onwards
W-CP-40 K/T/EVersion 4.11 onwards