Panel Guide
HKC SecureWave 1070 V1 & V2 – TTL
Panel Connection
|
Manufacturer |
HKC |
|
Model |
SecureWave |
|
Version |
1070 |
|
Minimum Panel Firmware |
V1, V2 |
|
Cable required? |
CS.1.204 |
|
Panel Profile |
HKC-SECUREWAVE812-TTL |
|
Panel Bus Connection |
TTL |
Panel Connection Information
|
Pin |
SPT |
Colour |
|
Pin 2 |
R-TTL |
Yellow |
|
Pin 3 |
TTL-T |
Black |
|
Pin 4 |
RTN |
Green |
Panel Programming
- Enter “Engineer” mode
- Make sure SP1 on the HKC panel is set up for Remote PC
- Enter “Communications” menu
- Communications Options Menu
- SP1 Port Options
- Set “Remote Access” to “Secure Access”
- Set “Local Access”
- Set “Printer Port”
- Make sure SP1 baud is set to 2400
- Data bits 8
- Stop bit 1
- NO PARITY (default)
- Go to “Communications” menu
- “Communication Service” menu
- “Port Settings”
- “Communications Service” menu
- To change remote user code from default
- Enter “Communications” menu
- Select “Remote User” menu
- Select “Remote User Code”
- RO1 Remote user will be displayed, set and verify this as 1234 or as required
- Notify CSL of the new code or set this using menu K on the DualCom Pro Communicator