This website stores cookies on your computer. These cookies are used to improve our website and provide more personalised services to you, both on this website and through other media. To find out more about the cookies we use, and information on how to block or delete cookies, please see our Privacy Policy. If you continue to use this site, you are consenting to our use of cookies.

Choose Language:

DualCom Pro Panel Guides

Panel Connection – RS232

Manufacturer RISCO
Model Agility
Version Agility 2, 3, 4 & 5
Minimum Panel Firmware V2.33
Cable required? RISCO LightSYS & Agility Cable CS.1.202
Panel Profile RISCO-AGILTY-V2/V3/V4 or V5-RS232
Panel Bus Connection RS232
Technical Notes

Pro will require an additional power supply due to no space for hardware and only having a 6V battery backup.

Important note - Serial integration with the RISCO Agility does not provide confirmed
alarms. If confirmed alarms are required please select GENERIC-MCM from the panel list in My Base, purchase a dial capture (MCM) card and use the appropriate RISCO PSTN modem.

Panel Connection Information

Pin SPT Colour
Pin 1 232-T Red
Pin 2 RTN Blue
Pin 3 R-232 Yellow

Panel Programming

  • Enter “Engineer Mode” by entering “Engineer Code”
  • [Scroll to (1) System] and press [#]
  • [Scroll ↓ to (2) Controls] and press [#]
  • [Scroll ↓↓ to (3) Communication] and press [#]
  • [Scroll ↓↓ to ARC ENABLE] and set to [N] and press [#]
  • [Screen shows (3) Communication] and press [#]
  • [Scroll ↓ to Config SW Enable] and set to [Y] and press [#]
  • [Screen shows (3) Communication] and press [#]
  • [Scroll ↓↓ to [FM ENABLE] and set to [N] and press [#]
  • Press [*] 2 twice. You are now in the Main Menu
  • [Scroll ↓↓↓ to (4) Communications] and press [#]
  • [Scroll ↓ to (3) Config. SW] and press [#]
  • Screen shows (1) Security and press [#]
  • [Scroll ↓ to (2) Remote ID] and press [#]
  • Modify value to [0000] and press [#]
  • Screen shows (2) Remote ID] press [*] press ↓
  • [Screen shows (2) Call Back] Press [#] and set Call Back En to [N] and press [#]
  • Press [*]
  • [Scroll ↓ (3) IP Gateway] press [#] into (1) IP Address] remove any IP Config
  • [Scroll ↓ (2) IP Port] press [#] Modify value to [00000] and press [#]
  • *** If you have a GSM module, remove setting from this menu ***
  • Press [*] 3 times
  • Screen shows (4) Communication
  • Exit “Engineer Mode” [0] and press [#] this saves the data

Troubleshooting

  • NOTE: RISCO Agility has two communication menus, please check you are in the correct
    communication menu during panel programming
  • NOTE: Panel integration only supports non-zone type alarms such as BV (Burglary Verified) on the following – DualCom Pro V2.25 & up and DualCom Pro 2 all FW versions