Panel Connection – DC09

Manufacturer

NOX System

Model

NOXOne and NOXCorporate

Version

 

Minimum Panel Firmware

R7

Cable required?

Ethernet Cable (CS.1.301)

Panel Profile

DC09-SIA-IP

Panel Connection

TCP/IP using IPv4

Technical Notes

 

DualCom Pro to Panel Wiring

The DualCom Pro can be powered from either OUT2 or OUT3 on the panel.

DualCom Pro Setup

The DualCom Pro is compatible with SIA DC-09-2021 and will transmit any SIA Alarms received, without modification, to the ARC.

The default values configured in the device are below and should be updated as appropriate:

Variable

Value

IP Address

DHCP

Subnet Mask

DHCP

Default Gateway

DHCP

DC09 Encryption Key

12345678123456781234567812345678

DualCom Pro DC09 IP Port

18000

DC09 Panel Timeout

95 seconds

Please contact CSL Technical Support who can assist in modifying the defaults if required.

Panel Setup

Use NOX Config to configure the panel for DC09.

Create a SIA-IP option.

Set the Receiver 1 address to the IP address of the DualCom Pro.

Set the port to 18000.

Under Settings

Check SIA IP DC-09.

Uncheck with MAC address.

Set an encryption key and ensure the same value is configured for the DualCom Pro.

Save the settings.

For alarm specific settings, please consult with the manufacturer and ARC.