MiniAir Quick Guide

Step 5 - Remote Arm & Disarm

Firstly, configure the panel as below:

1 - Configure a momentary/latching keyswitch – refer to manufacturer’s guide

2 - Wire OUT (orange wire) to the momentary/latching keyswitch of the panel

3 - Configure a programmable output from the panel to Activate (switch to ground) when the
panel is armed and to deactivate when disarmed – refer to manufacturer’s guide

4 - Wire the programmable output to IN (white wire) on the MiniAir

Please note: A relay may be required when configuring a panel with a latching keyswitch

Secondly, configure the App:

1 - Enable Open/Close reporting on the panel

2 - Enable arming/disarming from the settings menu on the My Home Alarm App

3 - Ask the customer to enter a remote pin of their choice

4 - Arm/Disarm from the panel’s keypad within 2 minutes to complete synchronisation