DigiAir Pro 3

Technical Specifications

Dimensions Radio: 75 mm (h) x 115mm (w) x 16mm (d)
LAN: 75mm (h) x 115mm (w) x 23mm (d)
Weight 106g excluding aerial
Temperature -10 °C to + 55 °C
Humidity 0 - 90% non-condensing
Mounting

Via fixing points under main cover 

Warranty Please refer to our terms and conditions.
Power Requirement

10 - 36 Volts.

In order to maintain compliance with requirements for electrical safety the Dualcom Pro should always be powered from a fused supply with following rating:

• For a 12V DC system (supply voltage in the range 10 Volts DC to 14 Volts DC) a fuse rated at 1.25

• For a 24V DC system (supply voltage in the range 20 Volts DC to 36 Volts DC) a fuse rated at 600 mA

If the power source is not limited to these values, then a fuse with the correct rating must be fitted in line with the positive connection from the power source.

The SPT will shut down on detecting a low supply of 7.6 Volts DC +/- 0.5 Volts DC

Current Consumption

DigiAir Pro 3 Radio attached to Security Panel: 66 mA (average value)

DigiAir Pro 3 Radio attached to Fire Panel: 55 mA (average value)

DigiAir Pro 3 LANattached to Security Panel: 78 mA (average value)

DigiAir Pro 3 LAN attached to Fire Panel: 62 mA (average value)

Radio Path 2G, 3G, 4G
Output Ratings

Maximum applied voltage = 60V

Maximum current = 150mA

Aerial 50 ohms (nominal) on MMCX socket
Operation Method Store and forward
CIE Interconnections Input triggering (standardised parallel), RS232, RS485, TTL
RCT Protocols Surgard MLR2
Input Terminals Max +30 Volts, Min 0 Volts DC (reference supply 0V) with a + or – 40% change for > 200ms.
User Serviceable Parts There are no serviceable parts within the DualCom Pro Range
Applicable Standards

Suitable for use in alarm systems complying to:

  • EN50131-1:2006+A2:2017
  • EN50136-1:2012+A1:2018
  • EN 54-21 LAN (Type 1): D4, M4, T5, A4, S0, I0
  • EN 54-21 GSM (Type 1): D4, M4, T3, A4, S0, I0
  • PD6662:2017
  • PD6669:2017

Emissions Standard – Radio Equipment Directive 2014/53/EU (RED) EN 50130-5 Environmental Class II

ATS Classification EN 50136-2:2013 SP2, SP3, SP4

ATS Configuration EN 50131-10:2014 Type Y

ATS Classification EN 50136-1-1:1998

  • Radio D3, M3, T4, S2, I3, A4 (ATS5)
  • LAN D3, M3, T5, S2, I3, A4 (ATS5)

DIGIAIR PRO 3

PATH AVAILABLE GRADES WHAT'S IN THE BOX PART NUMBER

Radio

SP2

DigiAir Pro 3, serial cable & small aerial

CS.51.R2

LAN

SP2

DigiAir Pro 3, serial cable & small aerial

CS.51.L2

23
DigiAir Pro 3
CSL DualCom ltd.
Building 4, Croxley Park, Hatters Lane, Watford, WD18 8YF
DoP No. 2544-CPR-30940-F01-22

EN 54-21:2006

Fire detection and fire alarm systems / Alarm transmission and fault warning routing equipment

EN 50131-10:2014
EN 50136-1:2012/A1:2018
EN 50136-2:2013
PD6662:2017 / PD6669:2017

Type of transmission system:
Type 1

SP5

Security Grade: 1- 4 depending on the I&HAS housing in which it is installed.
Environmental Class: II
www.csl-group.com