CSL Connected Orisec

ARC CONNECTION

CSL Connected allows you to connect the following control panels to your chosen ARC via Orisec Cloud Services: CP/CK/CT-20, CP/CP/CK-60, W-CP-40-K/T/E, CP-50/100/200. Communication can be made in SIA II, SIA III*, Contact ID or Fast Format, using the applicable communication device (Single path
modules - CM2-GSM, CM2-IP, CM2-Wi-Fi. Dual path modules - CM2-GSM-GSM, CM2-GSM-IP, CM2-WiFi-GSM).

*SIA III is the preferred signalling method.

PANEL PROGRAMMING

Within the Orisec engineering menus, navigate to the following sections to program the required information:

  • Programming Menu

  • Coms Modules

  • GSM settings (for all variants which include GSM)

    APN Name
    -geminit2.m2m

    User / APN2 - geminivf.com (only required if using dual radio - otherwise leave blank)

    APN Password - leave blank

    Note - if DHCP is being utilised, no information is required in these menus

    Ethernet settings (for all variants which include LAN)

    Address - add site IP details if required

    Port - add site IP details if required

    Mask - add site IP details if required

    Gateway - add site IP details if required

    Note - if DHCP is being utilised, only the router’s SSID and pasword are required in these menus

    Wi-Fi settings (for all variants which include Wi-Fi)

    SSID - Enter the router’s SSID

    Password - enter Wi-Fi password

    Address - add site IP details if required

    Port - add site IP details if required

    Mask - add site IP details if required

    Gateway - add site IP details if required

  • Programming Menu

  • System Options

  • Monitor H/W

  • Enable both these options
    - Report Single Path Fault
    - ATS Path Faults

SINGLE PATH SYSTEMS

  • Programmming Menu

  • ARC setup

  • ARC: 1
    Number - Enter ARC code from page 2
    Account - enter chip/account number from ARC
    Protocol - enter chosen protocol - default SIA III
    Dial Seq - enter 555

DUAL PATH SYSTEMS

  • Programmming Menu

  • ARC setup

  • ARC: 1
    Number - Enter ARC code from page 2 followed by DP grade (ie 12345DP2)
    Account - enter chip/account number from ARC
    Protocol - enter chosen protocol - default SIA III
    Dial Seq - enter 555

ARC CODE ARC CODE ARC CODE
1st County Monitoring 26747 DS Operations 37687 QVIS Monitoring 78447
4i Security 44650 East Midlands Central Station 32749 RE:SURE Intelligence 73440
Abel Alarm Company 22567 Farsight Security Services 32058 Regio 73046
Advanced Signal Monitoring 27649 Fenix Monitoring 33647 Scamp Security 72232
AIM Manchester 24654 G4S Belfast 44786 Scutum Digital Harlow 93617
Alarm Control 24 25242 G4S Dublin 44562 Scutum Digital Plymouth 73734
Alarm Meldnet BV 63556 GB Monitoring 42699 Securi-plex 31731
ARC Monitoring 27264 Marlowe 62529 Securitas 73283
Aspire Monitoring Services 26125 MCM Cork 62630 Sefton Security Services 73330
BHP 24030 Mercury Security Management 63732 Senate Group 73192
Bouygues 26018 MiTec 64763 Sharp Group Fire and Security 74218
Britannia Monitoring Service 34782 Morgan Verne 66431 SitexOrbis 74744
BSecure Monitoring Solutions 27357 MPL Alarm & Communicatie Centrale BV 67594 Smart Monitoring 76720
Cerberus Security & Monitoring 23514 MVTEK 68020 SMC (Custodian) 76270
Chubb Ireland 25750 National Monitoring Network 62766 SMC Nederlands (SMCNL) 76324
Chubb UK 24708 National Monitoring (UK) 62098 Southern / Northern Monitoring 76527
Churches 24183 Nederlandse Veiligheidsdienst Groep 68445
Connelly Glasgow 26630 Netwatch Ireland 63668 SSS Management Services 77774
Corps Monitoring Centre 26492 NightGuard 64455 The Shield Group 74430
Cougar Monitoring 26500 P&R Fire & Security 72789 Tyco Netherland 86537
Crime Prevention Services 27732 Pointer - Glasgow  76473 Uniqwin 86400
Crimewatch Monitoring Services 27463 PraxIS Group N.V 77222 ViewControl 84356
Devision Netherlands 33482 Professional Witnesses Limited (PWG) 77628 VPS 22450
Diamond Point Ltd 34294

ACCESS THE APP

CSL Connected is fully compatible with all Orisec applications, Control Plus, Control Plus 2, Orisec UDL & Orisec Cloud Services.

For additional information on Orisec control panels, software packages or technical support please contact Orisec:

Email: support@orisec.co.uk
Phone: 01706 398740

TROUBLESHOOTING

Q. My ARC does not appear in the list provided?
A. It may be that your chosen ARC is not one of the many ARCs that have signed up for this solution. Please contact CSL echnical Support.

Q. What grade is the product?
A. Single path units are sold as EN50136-1:2018 SP2. Dual path units are sold as EN50136-1:2018 DP2

Q. How do I know that my signals are being sent to CSL’s Gemini Platform?
A. Once you have your system on test with the ARC, enter the programming menu, select test and diagnostics and then do test calls. Whilst in this menu push enter on any test signal and ensure that 2 ticks are shown on the panel. This indicates that the test alarm has been sent to Gemini. You should always check with the ARC that they have received signals at their end too.

Q. Am I able to send signals in a different format to the one which was ordered?
A. Yes this is possible and can be selected in the panel. Please check with your ARC before making any changes to make sure that they will accept the new format.

Q. What set up do I need to do on the Orisec Cloud Services?
A. There is no set up required on Orisec Cloud Services.

Q. Why can I not see the second APN option in the panel menus?
A. For dual path devices the following software versions are required

CONTROL PANEL SOFTWARE VERSION
CP-20/ CP-60 Version 5.42 onwards
CK-20/ CK-60 Version 5.42 onwards
CP-50/ CP-100/ CP-200 Version 8.22 onwards
W-CP-40 K/T/E Version 4.11 onwards