This website stores cookies on your computer. These cookies are used to improve our website and provide more personalised services to you, both on this website and through other media. To find out more about the cookies we use, and information on how to block or delete cookies, please see our Privacy Policy. If you continue to use this site, you are consenting to our use of cookies.

Choose Language:

DualCom Pro Panel Guides

Panel Connection – RS232

Manufacturer RISCO
Model LightSYS
Version LightSYS, LightSYS II
Minimum Panel Firmware V1.62
Cable required? RISCO LightSYS & Agility Cable CS.1.202
Panel Profile RISCO-LITESYS-RS232
Panel Bus Connection RS232
Technical Notes

See troubleshooting below


Panel Connection Information

Pin SPT Colour
Pin 1 T Red
Pin 2 RTN Blue
Pin 3 R Yellow


Panel Programming

  • Login to Engineer Mode, exit/Menu Button, press Engineer Code and press OK
  • [Keypad shows 1] Programming and press OK
  • [Scroll to 1] System and press OK
  • [Scroll ↓ to 2] Controls and press OK
  • [Scroll ↓↓ to 3] Communication and press OK
  • [Scroll ↓↓ to ARC ENABLE] and set to 'N' and press OK
  • [Screen shows 3] Communication and press OK
  • [Scroll ↓ to FM] Enable and set to 'N' and press OK
  • [Screen shows 3] Communication and press OK
  • [Scroll ↓↓ to CS ENABLE] and set to 'Y' and press OK
  • Press Exit/Menu Button 2 twice you are now in the Main Menu
  • [Scroll ↓↓↓ to 5] Communications and press OK
  • [Scroll ↓ to 3] Config. SW and press OK
  • [Screen shows 1] Security and press OK
  • [Scroll ↓ to 2] Remote ID and press OK
  • Modify value to 00000 and press OK
  • [Screen shows 2] Remote ID Press Exit/Menu Button press ↓
  • [Screen shows 2] Call Back. Press OK and ensure NO PHONE NUMBERS are set
  • Press Exit/Menu Button x 4 times
  • [Screen shows 5] Communication
  • Now Exit/Engineer Mode 0 and press OK, this will save the data

Troubleshooting

  • NOTE: RISCO LightSYS has two communication menus, please check you are in the correct
    Communication Menu during panel programming.
  • Ensure upon initial panel start up that the language selection is used otherwise ARC Enable will
    not show under Communications Menu 3.
  • To amend this, go to [Programming][System][Settings][Customer] and change it from ‘0EN’ to
    ‘0UK’ (as it should be for us in the UK).
  • By doing this, they will forfeit the entire programming as the panel will invoke a full default for
    ‘UK’ settings.
  • NOTE: Panel integration only supports non-zone type alarms such as BV (Burglary Verified) on the following – DualCom Pro V2.25 & up and DualCom Pro 2 all FW versions