Nox – DC09
Panel Connection – DC09
Manufacturer | NOX System |
Model | NOXOne and NOXCorporate |
Minimum Panel Firmware | R7 |
Cable required? | Ethernet Cable (CS.1.301) |
Panel Profile | DC09-SIA-IP |
Panel Connection | TCP/IP using IPv4 |
DualCom Pro to Panel Wiring
The DualCom Pro can be powered from either OUT2 or OUT3 on the panel.
The DualCom Pro is compatible with SIA DC-09-2021 and will transmit any SIA Alarms received, without modification, to the ARC.
The default values configured in the device are below and should be updated as appropriate.
Please contact CSL Technical Support who can assist in modifying the defaults if required.
Default Values
Variable | Value |
IP Address | DHCP |
Subnet Mask | DHCP |
Default Gateway | DHCP |
DC09 Encryption Key | 12345678123456781234567812345678 |
DualCom Pro DC09 IP Port | 18000 |
DC09 Panel Timeout | 95 Seconds |
Panel Setup
Use NOX Config to configure the panel for DC09.
Create a SIA-IP option.
Set the Receiver 1 address to the IP address of the DualCom Pro.
Set the port to 18000.
Under Settings
Check SIA IP DC-09.
Uncheck with MAC address.
Set an encryption key and ensure the same value is configured for the DualCom Pro.
Save the settings.
For alarm specific settings, please consult with the manufacturer and ARC.